Road gullies                                                 BS 5911-6:2004 kitemarked

CPM Group Ltd offer a range of precast concrete road gullies with 150mm trapped outlets.

Gullies are produced monolithically on fully automated machines, providing a strong robust unit, needing no concrete surround and not subject to floatation.

For quick and efficient offloading, an attachment is available which can be quickly fitted to a standard forklift truck, or suitable mechanical offloader. The attachment enables concrete gullies to be handled and offloaded in pairs. 

Precast concrete road gullies can be supplied with adaptors for connection to clay or plastic pipes.

CPM Group Road Gullies picture 1

CPM Group Road Gullies picture 2

Gully weights and dimensions

Nominal
I/Dia
(mm)
A

Nominal Wall
Thickness
(mm)

Width
(mm)

B

Effective
Depth
(mm)
C

Capacity
(litres)

Weight
per Unit
(kg)

Outlet  I/Dia
(mm)
D

Approximate Measurement (mm)
E

No. per Full
23.5 Tonne Load

300*

35

600

450

14

120

150

250

195

300*

35

600

600

23

151

150

250

155

375

55

698

750

50

188

150

250

125

375

55

698

900

69

216

150

250

108

450

55

780

750

70

223

150

250

105

450

55

780

900

95

255

150

250

92

450

55

780

1050

120

287

150

250

81

*Not to BS 5911-6:2004

Gully cover slabs

Gully cover slabs are available in both square and ‘U’ shaped, with handling recesses for lifting brackets.

Slab

Dims

Kg’s

Square

750 x 650

80

U

585 x 650

50



CPM Group Road Gullies picture 4

The gully adaptor is:
A versatile elastomeric sealing adaptor ring manufactured in EPDM rubber to BS 2494 Type D.

Tolerant of a range of pipe diameters and profiles.
For use only with CPM Group kitemarked concrete gullies.

For pipes not included in table, the following criteria should be used for selection of correct gully adaptor.


CPM Group Road Gullies picture 3

No. 1501
No. 1502
           

Spigot diameter
Spigot diameter

160mm to 180mm
175mm to 190mm

To suit pipe

Type of pipe

Number of gully adaptor required to suit type of pipe

DN

1501

1502

160

uPVC pipe to BS4660

plastic

l

 

150

aquapipe - corrugated

plastic

l

 

150

ultrarib

plastic

l

 

150

twin wall PVC - corrugated

plastic

l

 

150

supersleeve

clay

l

 

150

densleeve

clay

 

l

150

hepseal

clay

 

l


Procedure for installation and selection of gully adaptor  

1. Ensure the gully outlet socket is clean. Any  hard points should be removed
   
2.

Fit adaptor into socket. The adaptor seals are designed slightly larger than the socket to ensure positive location and an effective seal. Care should be taken to even out the seal to remove folds, although if left, this will occur naturally.

   
3. Place pipe in adaptor and push home.
   
4. Smooth plastic pipe – requires no lubricant.
   
4i) Supersleeve pipe – can be jointed dry with care, but lubricant may be used to assist jointing
   
4 ii) Densleeve/Hepseal/Corrugated pipes - lubricant such as water/soap, silicone etc. is required for jointing purposes.  In some instances for corrugated pipes it may be advisable to place the pipe in the adaptor prior to its location in the gully outlet

 

CPM Group Road Gullies picture 5
 
CPM Group Road Gullies picture 6
 
CPM Group Road Gullies picture 7
 
CPM Group Road Gullies picture 8
 
 
 

 

 

  CPM News